Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	46
Date	08/12/14
Start Time	10:54:26
Diameter Midpoint
 10.9	415916
 11.3	426717
 11.8	474611
 12.2	529295
 12.6	572673
 13.1	637454
 13.6	665058
 14.1	689398
 14.6	718017
 15.1	730152
 15.7	727852
 16.3	719515
 16.8	703069
 17.5	674136
 18.1	631244
 18.8	589322
 19.5	535907
 20.2	477334
 20.9	416908
 21.7	360945
 22.5	305183
 23.3	249972
 24.1	199239
 25.0	157144
 25.9	120670
 26.9	90106.7
 27.9	63437
 28.9	43200.8
 30.0	28651.6
 31.1	18843.1
 32.2	11956.5
 33.4	6863.24
 34.6	3881.11
 35.9	2301.82
 37.2	1343.58
 38.5	822.509
 40.0	509.64
 41.4	354.876
 42.9	290.949
 44.5	162.142
 46.1	419.142
 47.8	589.112
 49.6	774.136
 51.4	593.046
 53.3	522.027
 55.2	690.23
 57.3	940.825
 59.4	1787.2
 61.5	2693.99
 63.8	3742.34
 66.1	4570.58
 68.5	4789.15
 71.0	5058.15
 73.7	5074.61
 76.4	5018.95
 79.1	4623.37
 82.0	4078.86
 85.1	3376.64
 88.2	2556.88
 91.4	1895.14
 94.7	1390.3
 98.2	1064.74
101.8	774.649
105.5	597.37
109.4	429.124
113.4	315.455
117.6	264.317
121.9	218.594
126.3	117.266
131.0	150.481
135.8	107.928
140.7	86.541
145.9	72.5451
151.2	63.1698
156.8	55.1318
162.5	53.9354
168.5	69.5499
174.7	56.4714
181.1	68.4242
187.7	23.3444
194.6	34.031
201.7	33.4426
209.1	39.8839
216.7	30.5633
224.7	24.6639
232.9	28.3209
241.4	29.582
250.3	30.4771
259.5	18.0779
269.0	17.7895
278.8	11.3815
289.0	21.312
299.6	14.1446
310.6	14.7757
322.0	20.262
333.8	14.7712
346.0	4.26709
358.7	10.8531
371.8	10.2217
385.4	5.0717
399.5	2.54486
414.2	9.2757
429.4	15.4044
445.1	5.94134
461.4	7.32386
478.3	2.49101
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1756
High Voltage	9864.2
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	15.9219
Mean(nm)	16.8547
Geo. Mean(nm)	16.2448
Mode(nm)	15.1247
Geo. Std. Dev.	1.28748
Total Concentration(#/cm)	1.30607e+007
Comment	